First of all must understand the series of partial pressure, shunt shunt principle. Therefore, for low voltage neon need to be used in high voltage environment, we must series one (or two) current limiting resistor for partial pressure. So that the actual voltage through the neon is very low, to achieve the neon normal operating voltage.
Calculation formula of current limiting resistor R:
R=U1-2U/I (KΩ)
Type medium: U1--power supply voltage, Unit: V;
U2--Neon initial voltage, unit: V;
I-Neon working Current, Unit--ma
Example: Using NBO-4C type neon, its u1=220v,u2=60v,i=0.5ma
R= (220-60)/0.5=320 (KΩ)
In general, the RJ-0.25w-330kω resistor
Honyone Electrical aplliance CO.
LTD. Huizhou Hongli Source Electrical Appliance Co., Ltd. Technical Department provides